| MODEL: SUNPX- | ANALOG OUTPUT (4-20mA or 0-1Vdc) | DIGITAL OUTPUT (RS-485 Half Duplex) | ||||||
|---|---|---|---|---|---|---|---|---|
| -ATi | -ATHi | -AAP | -ACo2 | -DTi | -DTHi | -DAP | -DCo2 | |
| Measure. Channel | 1Ch | 2Ch | 1Ch | 1Ch | 1Ch | 2Ch | 1Ch | 1Ch |
| Sensor | Internal Digital | Internal Digital | External Digital | External Digital | Internal Digital | Internal Digital | External Digital | External Digital |
| Measure Parameter | Temperature | Temp/Humidity | Ambient Pressure | Co2 | Temperature | Temp/Humidity | Ambient Pressure | Co2 |
| Measure. Range | -20 to 70°C | 0 to 60°C 0-100%Rh |
0-1200Pa | 0-5000ppm | -20 to 70°C | 0 to 60°C 0-100%Rh |
0-1200Pa | 0-5000ppm |
| Measure. Accuracy | ±0.3°C | ±0.2°C ±2%Rh at 25°C,50%RH |
±1Pa | ±50ppm | ±0.3°C | ±0.2°C ±2%Rh at 25°C,50%RH |
±1Pa | ±50ppm |
| Display Resolution | 0.01 | 0.01 | 0.1 | 0.1 (0-999ppm) 1 (above 999ppm) |
0.01 | 0.01 | 0.1 | 0.1 (0-999ppm) 1 (above 999ppm) |
| Measure. Interval | 5s | 5s | 5s | 30s | 5s | 5s | 5s | 30s |
| Output type | 4-20mA or 0-1V (1ch) | 4-20mA or 0-1V (2ch) | 4-20mA or 0-1V (1ch) | 4-20mA or 0-1V (1ch) | RS-485 (1ch) | RS-485 (2ch) | RS-485 (1ch) | RS-485 (1ch) |
| Warm-up / Response | < 2min < 10s |
< 2min < 10s |
< 2min < 10s |
< 2min < 10s |
< 2min < 10s |
< 2min < 10s |
< 2min < 10s |
< 2min < 10s |
| Power | 2W(+ ,T) 3W(+ ,T,G) |
3W(+ ,T,H) 4W(+ ,T,H,G) |
3W(+ ,T) 3W(+ ,T,G) |
2W(+ ,T) 3W(+ ,T,G) |
4W(+ ,D,+ ,D,- ,G) | 4W(+ ,D,+ ,D,- ,G) | 4W(+ ,D,+ ,D,- ,G) | 4W(+ ,D,+ ,D,- ,G) |
|
Size & Material: 175mm (L) x 16mm dia. Housing: wall mount ventilated ABS Enclosure for some models external probes are connected Operating Environment: Temperature: -20°C to +60°C; Humidity: 0-100% RH |
||||||||