We are Supplier, Exporter of Pressure Sensors MSI M5200 and our set up is situated in Pune, Maharashtra, India. The M5200 pressure transducers from the MicrofusedTM line of MEAS, with their modular design, offer maximum flexibility for different configurations. This latest series sets a new price performance standard for demanding commercial and heavy industrial applications. This series is suitable for measurement of liquid or gas pressure, even for difficult media such as contaminated water, steam, and mildly corrosive fluids.
The wetted material is made of 17-4 PH stainless steel and the transducer's durability is excellent with no o-rings, welds or organics exposed to the pressure media. The M5200 is weatherproof and exceeds the latest heavy industrial CE requirements including surge protection. The circuit is protected from reverse wiring at input and short circuit at output.
This product is geared to the OEM customer for low to mid volumes. MEAS stands ready to provide a custom design of the M5200 where the volume and application warrants. Additional configurations not listed are either available or possible. Please inquire for further information.
Parameters | Min. | Typ | Max. | Units | Notes |
Accuracy
( combined non linearity, hysteresis, and repeatability ) |
-0.25 | 0.25 | %F.S. | BFSL | |
Isolation, Body to any Lead | 100 | MΩ | ©500VDC | ||
Dielectric Strength | 2 | mA | ©500VAC, 1min | ||
Pressure Cycles | 1.00E+ 6 | 0-FS Cycles | |||
Proof Pressure | 2X | Rated | |||
Burst Pressure | 5X | 20k psi | Rated | ||
Long Term Stability (1 year) | -0.25 | 0.25 | %F.S. | ||
Total Error Band | -1.0 | 1.0 | %F.S. | Over compensated temperature range | |
Compensated Temperature | -20 | +85 | °C | ||
Operating Temperature | -40 | +125 | °C | Except cable 105°C max | |
Storage Temperature | -40 | +125 | °C | Except cable 105°C max | |
Load Resistance (R L) | RL > 100k | Ω | Voltage Output | ||
Load Resistance (R L) | < (Supply Voltage -9V) / 0.02A | Ω | Current Output |
||
Current Consumption | 5 | mA | Voltage Output | ||
Rise Time (10% to 90%) | <2ms (Voltage Output); <3ms (Current Output); Without Snubber | ||||
Wetted Material | 17- 4PH Port, 316 Stainless Steel Snubber | ||||
Gage Pressure Reference Vent | Under 1k psi, customer to ensure venting through mating connector | ||||
Bandwidth | DC to 1 KHz (Typical) | ||||
Shock | 50g, 11 msec Half Sine Shock per MIL - STD -202G, Method 213B, Condition A | ||||
Vibration | ± 20g, MIL-STD-810C, Procedure 514.2, Fig 514.2-2, Curve L |
Range ( psi ) | Range ( Bar ) | Gage | Sealed | Compound |
0 to 050 | 0 to 3.5 | • | • | |
0 to 100 | 0 to 007 | • | • | |
0 to 200 | 0 to 014 | • | • | |
0 to 300 | 0 to 020 | • | • | |
0 to 500 | 0 to 035 | • | • | |
0 to 01k | 0 to 070 | • | • | • |
0 to 03k | 0 to 200 | • | • | • |
0 to 05k | 0 to 350 | • | • | • |
0 to 07k | 0 to 500 | • | • | • |
0 to 10k | 0 to 700 | • | • | • |
0 to 15k | 0 to 01k | • | • | • |